Waterproof Probes
Sealed for use underwater at depth even in diving gloves. Ferrous probes measure non magnetic coatings on ferro-magnetic substrates Elcometer 456 ferrous gauges accept any ferrous probe. Non-ferrous probes measure non conductive coatings on non-ferrous metal substrates and Elcometer 456 non-ferrous gauges accept any non-ferrous probe. Dual FNF probes measure both ferrous and non-ferrous application with automatic substrate detection. Elcometer 456 FNF gauges accept all ferrous, non-ferrous and dual FNF probes. Elcometer probes have a maximum operating temperature of 80° C (176° F) with the exception of separate ferrous probes 150° C (300° F) and Hi-Temperature PINIP's 250° C (480° F). The stated temperature is the substrate temperature, and the duty cycle of the probe must be reduced to ensure a minimal temperature build-up within the probe. All Elcometer probes are supplied with a test certificate and a set of calibration foils appropriate to the scale range of the probe.
Price: $1,019.00
More Details
Designed to work with any of our Ferrous or Dual FNF Elcometer 456 Separate Gauges.
For higher resolution & accuracy on thin coatings Scale 2 gauges can be switched to the Scale 1 mode measurement performance.
Sealed for use under water at depth.
Large diameter probe sleeve for use with diving gloves.
Suitable on both flat and curved surfaces.
Specifications:
15 foot cable Range: 0-200 mils (0-5mm) Accuracy: ±1-3% or ±1.0 mil (±20µm) Resolution: 0.1 mil: 0-50 mils; 1mil: 50-200 mils (1µm: 0-1mm; 10µm: 1-5mm) Minimum convex surface radius 4mm (0.16") Minimum concave surface radius 40mm (1.98") Minimum headroom 138mm (5.43") Minimum sample diameter F Mode: 8mm (0.32")
Price: $1,339.00
More Details
Designed to work with any of our Ferrous or Dual FNF Elcometer 456 Separate Gauges.
For higher resolution & accuracy on thin coatings Scale 2 gauges can be switched to the Scale 1 mode measurement performance.
Sealed for use under water at depth.
Large diameter probe sleeve for use with diving gloves.
Suitable on both flat and curved surfaces.
Specifications:
45 foot cable Range: 0-200 mils (0-5mm) Accuracy: ±1-3% or ±1.0 mil (±20µm) Resolution: 0.1 mil: 0-50 mils; 1mil: 50-200 mils (1µm: 0-1mm; 10µm: 1-5mm) Minimum convex surface radius 4mm (0.16") Minimum concave surface radius 40mm (1.98") Minimum headroom 138mm (5.43") Minimum sample diameter F Mode: 8mm (0.32")
Price: $1,549.00
More Details
Limited Availability
Designed to work with any of our Ferrous or Dual FNF Elcometer 456 Separate Gauges.
For higher resolution & accuracy on thin coatings Scale 2 gauges can be switched to the Scale 1 mode measurement performance.
Sealed for use under water at depth.
Large diameter probe sleeve for use with diving gloves.
Suitable on both flat and curved surfaces.
Specifications:
98 foot cable Range: 0-200 mils (0-5mm) Accuracy: ±1-3% or ±1.0 mil (±20µm) Resolution: 0.1 mil: 0-50 mils; 1mil: 50-200 mils (1µm: 0-1mm; 10µm: 1-5mm) Minimum convex surface radius 4mm (0.16") Minimum concave surface radius 40mm (1.98") Minimum headroom 138mm (5.43") Minimum sample diameter F Mode: 8mm (0.32")
Price: $2,279.00
More Details
The all New Elcometer 456 Straight Ferrous Probe - Scale 2 (164 foot cable) is designed to work with our Elcometer 456 Separate Gauges.
For higher resolution & accuracy on thin coatings Scale 2 gauges can be switched to the Scale 1 mode measurement performance.
Sealed for use under water at depth.
Large diameter probe sleeve for use with diving gloves.
Suitable on both flat and curved surfaces.
Specifications:
164 foot cable Range: 0-200 mils (0-5mm) Accuracy: ±1-3% or ±1.0 mil (±20µm) Resolution: 0.1 mil: 0-50 mils; 1mil: 50-200 mils (1µm: 0-1mm; 10µm: 1-5mm) Minimum convex surface radius 4mm (0.16") Minimum concave surface radius 40mm (1.98") Minimum headroom 138mm (5.43") Minimum sample diameter F Mode: 8mm (0.32")
Price: $2,699.00
More Details
Designed to work with any of our Ferrous or Dual FNF Elcometer 456 Separate Gauges.
For higher resolution & accuracy on thin coatings Scale 2 gauges can be switched to the Scale 1 mode measurement performance.
Sealed for use under water at depth.
Large diameter probe sleeve for use with diving gloves.
Suitable on both flat and curved surfaces.
Specifications:
75 meter cable Range: 0-200 mils (0-5mm) Accuracy: ±1-3% or ±1.0 mil (±20µm) Resolution: 0.1 mil: 0-50 mils; 1mil: 50-200 mils (1µm: 0-1mm; 10µm: 1-5mm) Minimum convex surface radius 4mm (0.16") Minimum concave surface radius 40mm (1.98") Minimum headroom 138mm (5.43") Minimum sample diameter F Mode: 8mm (0.32")